We purchased a Hayward Pump SP3220EE and I need to know how . Troubleshooting your Hayward salt system Piscines Trvi 8.88K subscribers Subscribe 57K views 3 years ago A salt water system control panel provides all sorts of information. Thanks for the help. Within the underground world of Japan, and the world at large, a certain man is known as the Evil Emperor. It could also be due to the air intake, or the filter pressure, Water around the base, check the motor bolts or seal plate clamp for tightness on the seal plate o-ring, and check drain plugs for tightness, but most likely its coming from around the outlet pipe, and dripping down to the base, or from the shaft seal, which leaks directly mid bottom, where motor connects. When I go to backwash the filter pump shuts down. "author": {
I changed my sand a few weeks and tested it and it worked fine. Filter or pump baskets are dirty. Please help! Power can be checked at the motor terminals, with a multimeter set to AC volts. It is usually set to run at high rpm early morning and that is before sun hits it. Hi Tammy, could be many things. The higher the pump is elevated above the water level, the more struggles this can cause. All the leds remain off and the display shows the salt concentration 2900. I used electrical tape so the impeller Probably not your pump basket being full causing this but improper air flow caused by debris/dust. All breakers have some wiggle to them usually, but a very loose breaker could be a hazard for arcing or even fire so should be checked out, if so. Third time turned off pump same thing happened with humming and eventually kicking in. Examine your pumps impeller for any obstructions, and replace the capacitor if necessary. Guess I was wrong. Usually get 3-4x that long. Humming noise is usually associated with a bad capacitor, a black cylinder at 9 oclock in the rear of the motor. Hayward offers environmentally responsible, cutting-edge pool and spa equipment for residential and commercial, in-ground and above-ground pools. Hi Heidi, it sounds like maybe the plumbing could be reversed? We opened the pool this spring and the pressure rises after 15 to 20 minutes. rialto grand polished porcelain tile 12x24, platypus gravityworks water filter system kit 2-liter, trinity basics ecostorage 5-tier nsf certified rack, Armstrong Human Resource Management 13th Edition Pdf, what is the newest lens for cataract surgery. I just bought this pump 3-4 yrs ago? On high it seems fine. Thanks, good question. Hi Todd, that would be rare but not impossible sometimes bearings are not set perfectly, or manufactured perfectly, or the tolerances of the bearing housing could be off by a hair, from something being loose, or mis-shaped or if the motor were dropped from a height. Ray1davis@comcast .net. A leaking shaft seal should not cause your filter pressure to decrease. },
Gasket Maker. Hello , This is an inactive thread. You can also check that the phone cord wire is plugged into the interface, on underside. search, pool & drain cover safety Hi Davy, If the wiring is Ok and the error persists, replace the sensor. New pump, was running fine. gives you instant access to PDF files. I have a new above ground pool with a Hayword pump. When we turned it on heard a pop and blew fuse. Factory Direct Pricing Whichever brand they go with, we know that our customers are always looking to get the best price. Now when it is turned on it works for a few seconds then stops pumping and makes a humming sound. A local electric motor shop should have them, or easy to find online. All-In-One Sanitization Then there is often a switch or a timeclock that is wired in between the sub-panel and the pump. Weve tried everything. The most likely is an air leak, and the usual places are 1) pump lid not tight enough or not lubed, or bad o-ring, or loose drain plugs (or without thread sealant or o-ring). Well it so happens that I am having the exact same issue with the new cell. Use a flashlight, and you should see gears moving thru the small view hole. Its just a trickle (as opposed to a spray)at this time. Could be the use of a clarifier or flocculent that is clogging the sand? Did you rewire the time clock too, or just the pump motor? Could vibration over time wear the pump housing? It was only 3 years old. It is being practiced by thousands of pool owners just like you. Every time I vacuum my pool and then back wash and rinse. Pumps can also leak water from the shaft seal, which can appear to be a housing/seal plate leak, but will leak only directly from the bottom. The cell is new. I have an aboveground kayak saltwater system . Third, could be clogging in the filter, or bad filter sand, if you have a sand filter. Check the tightness on all wire connections, on the breaker, timeclock and motor. Is this normal or is there a malfunction? Any advice?? Put your power leads on both sides of the transformer, should be 115V IN, and 28V OUT, (or close to those numbers). You must log in or register to reply here. Just purchased a Hayward SP32002VSP. Or the filter cartridge may need to be replaced, and is clogged with minerals/dirt/oil, and creating the high pressure itself. I dont see that code listed. Don, melted shrouds can indicate that the something may be laying on the burner tray, causing flames to shoot out a little sideways, or something is laying on (or clogging) the heat exchanger, allowing hot gas to build up inside the heater, slowing down the exhaust rate. Do you know what the problem is? Pump lids are often easier to remove when the Filter Air Bleeder is opened, to relieve vacuum pressure. have the pump motor rebuilt by replacing the bearings and shaft seal, or having an electric motor repair shop do it for you, or 2) replace the motor with an exact replacement motor + new shaft seal, or 3). Can you help? "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
We have an Hayward SP1580X15 Power-Flo LX 1.5hp pump. In most cases, it means that your motor is on the way out. "@type": "ImageObject",
Our variable speed Hayward pump, when not running on highest speed, keeps resulting in FLO errors. }
. No power not even a humming. Hi Dave, the square gasket for the lid, can sometimes come out of the groove on a Superpump, Id check that first, and make sure the lid is very tight. If all good, check the capacitor, at 9 oclock, looking for bulging or cracking or burned marks. Replacement of the gasket inside the valve is the fix. If it continues, a new o-ring might be the ticket, yes. Hayward, Create a Pool Owner Profile, Create a Pool Professional You could also check incoming voltage, and wire connections, as fluctuating current can cause an overheated motor, but if its very old, it may just be on its way out, sorry to say at which point you could replace just the motor and shaft seal, or the entire pump. Entire pump system with pump basket and housing. It would run fine. runs normal on 110 but does not make any sound when set on 230 and wired accordingly. It looks like its coming from in between the motor and pump.Am I correct in thinking I need a new seal plate kit? bought a SP2610x152s super pool pump 1.5 hp. from Did I mention low water level, stuck skimmer weirs, or clogged skimmer baskets? Bobby, yes that would rule out the power source, or the outlet as being the problem. I hope to hear back from you of and to in a is " for on that ) ( with was as it by be : 's are at this from you or i an he have ' not - which his will has but we they all their were can ; one also the dr myers ultrasound. Plaster and vinyl surfaces in particular, can become damaged when exposed to hot summer weather, and stained, if that applies or matters in your case. Hi Shelly, sounds like maybe the board got wet, or there is a loose connection, or power supply issues. 6. Now that i have my new liner in and pool is filled i started adding chemicals to the pool and i went to turn the switch on and there is nothing happening with the motor. "height": "219",
I also made sure that the board was changed from T9 to T3 cell. Any new postings here are unlikely to be seen or responded to by other members. Is there a reset button or do I just need to wait until the water evaporates and it should turn back on? Fans of space opera and world-building fantasies will find this first book in the series compelling, concluding with a powerful vision of world-changing gods and attempts to free Eden from its curse that conclude in a cliffhanger for future books to explore. Hi, it could be the filter, and if so, the pressure on the gauge would be high during operation usually. It is so poorly designed and the helper handle is basically useless because it bumps into the outlet flow tube and the jandy. The arrow at the top of the hex nut points in the direction of the water flow. That could explain the pumping problems. Hi Tim, smoke from the motor? When it shuts off, you could also test power, to be sure power is still reaching the motor, with a multimeter tester. I replaced the entire pump motor and the same thing happened. Hi Patrick, so you have power from the breaker to the timer and to the switch. Same thing if I try to backwash. Gail, good luck! If your cell looks like 4A, continue to Step 4. Use jumper wire to jump TH terminals. My pump motor runs for 3-5 minutes ant then shuts off for about the same time. Or could it be a dirty motor or ground wire that isnt connected well enough? Also check that the wires on the front, from breaker and to pump, are tightly secured, and no burn marks. Should have the hard plastic side facing the motor and the soft rubber side facing the impeller. Products, Parts To fix the problem, manually reset the Inspect Cell LED. Step 1: Check your system to confirm that you have programmed the correct cell size. Thanks. Davy, Morning , everything was working fine with my Hayward pump. Now if its not an air leak, surging can also be caused by a clog in the pipe, usually a solid object like a golf ball, getting sucked back and forth in the pipe. Hi Davy~ Display seems to be reading correctly and shows the cell is not generating. Hello, my salt generator seems to be always be producing at 100% no matter what my output dial is set at. Pump is 29 years old so wouldnt surprise me if impeller is failing. Gas fired pool heaters are similar to a home gas-fired furnace, with the main difference being that a pool heater heats water and a home furnace heats air. But your superpump is fine on your AG pool. Using a circuit tester, I determined that the timer and the inline switch has power. YOu can shim under a piece of rubber, or carpet, or cardboard which wont last long, but anything between the pump and the pad should quiet the pump, and take up space to prevent the vibration. I believe there a water volume calculator, that can help us size the motor, the originally company who installed is not in business. GFCIs are sensitive, but for a reason. Hi Ann, in such cases, I would probably use a plumbers Pipe Wrench or very large Channel Pliers may work, or I have seen custom tools home-made from 24 wood, that fit over the ridge on the lid, with a few inches on either side to push on, or tap with a hammer. . 2. loose pipe coming into pump, drawing air around fitting threads Holding the shaft stationary (so it wont turn), unthread the impeller, counter clockwise, to remove. Also check all the wires, from the back of the terminal board, to the stat. Thanks again! When it stops again, you may want to pull off the filter valve from the filter, and inspect the top few inches of sand, maybe replacing it with new. See if the pump motor shaft spins freely, to rule out a motion issue. Anyway, have you checked the cleaner line strainer? When I turned the pump on it is very loud and the pump is not moving water. Bump shaft or diaphragm gasket? What would the problem be? Have an old Hayward super II pump, worked fine last fall, this spring at startup very low volume. I replaced the capacitor last year. They dont usually begin to flow like a gusher, but a steady trickle. Hi Mike, after backwashing a DE filter, you need to add DE filter powder again. Changed lid gasket and plugs in basket still same issue. The fact that it runs all day fine with a HD power cord attached and plugged in, makes me think its not a motor issue. Hi Rudy, clicking on/off sounds like the switch in the rear of the motor, you may find either the centrifugal switch (dead center) or the stationary switch (6 oclock), may not be fully disengaging, or may be loose or bent. low speed works fine, pump is three years old. If you see an increase in pump pressure, ensure that there is no blockage preventing the flow. Are I on the right track? My Hayward h250 propane heater keeps blowing fc1 and fc2 fuses immediately after plugging in. PowerFlo LX is not a self-priming pump (Hayward PowerFlo II is self-priming), which means it has trouble lifting water vertically. My Hayward mother is a 1.5 hp. Almost ordered a new pump but it really sounded good. Hi Tom, If the filter and pump are located below the water level of the pond, you could open up the pump lid or remove the filter drain plug, and the pond should gravity drain. I have a Hayward H250 pool heater with a digital display. If not, you should cut out the fitting and replace, smearing on some Blue RTV sealant, and then wrapping the threads completely in 3-4 layers of Teflon tape before screwing it into the pump. I have a hayward superpump and upon starting the pump, it sucks the water into the pump basket but when it is filled with water the pump will start revving up and down. You should get it back same day or next day, in most cases. IF that all looks good, consider replacing the capacitor. I have a t-15 cell. Motor will hum for a few seconds and eventually trip the breaker. Hi Mike, pumps are too hot to touch normally, running at 140 or so. I am a novice with in ground pools, but is the pool motor supposed to run continuously? Make sure that the drive is bonded with the bare copper wire and all four screws are secure on the drive. The ampage to the pump has been the same since we got the pump 7 years ago and never had this issue before. Does anyone know what Im talking about and/or know how to repair? Fix this problem simply by tightening or adjusting the wires and connections in the motor. Most above ground pool pumps are not self-priming, and mot inground pumps are self-priming. Is there something I forgot to do? Finally, it could be bad voltage, but again, it was running before just fine, so probably not that. In the meantime, could you send me a link for the capacitor that I need? You may be able to remove the basket and reach thru the volute to the eye of the impeller, and may be able to feel debris. Hi Ryan, just use a small flathead screwdriver and wedge it between the cover and motor, and wiggle it back and forth, in a few spots around the edge, and pull off with your other hand. With the pump off, remove the basket and reach your hand back into the eye of the impeller. What happens when you switch the output to super-chlorinate? Im having an air leak problem with my pool. Ive had the pool for about a month and all has been fine but while I am ordering a new hose is there a replacement hose I can use in the meantime? Do you have to find the pump up with water before turning it on? Hope that helps! Hi Mike, when there is no wiring diagram printed on the motor label or above the nameplate, indicating High/Low Voltage wiring specs, then the motor is not reversible. If flame is sensed with the gas valve off the control will go into lockout. I replaced the start capacitor as that sounded like that was the most likely culprit based on everything I read, but noise still persisted. Reset AquaRite Salt Chlorination Inspect Cell Light If the Inspect Cell Light is the only LED light flashing, then you can reset it by simply holding down the diagnostic button for 3 seconds, then release. If a LED is flashing, wait 60 seconds after starting the filter pump. Do I need to prime it? in the filter. Hi! Check the motor vent holes, (bottom front) to be sure they are not clogged. my two speed Hayword pump clicks when Going to try 2 hrs low and 6 high. If you like the Perflex filter, go with the Perflex EC75A, which is rated for 80 GPM, EC65A is only rated for 67 gpm. My check salt generator station even after I clean it out. Hi Andy, breakers are not usually screwed down, they snap in place, you can try pushing firmly on the front of the breaker with fingers, to be sure it is seated properly.
Riverside Baseball Field,
Fremont Place Selling Sunset Emily,
Texas Railroad Commissioner 2022,
Articles H